 3相分の電流を一括して変流器に通すと、3相分の電流をベクトル合成した電流が2次側に流れます。ベクトル合成された電流はどうなるのでしょうか?実は対称3相交流3相分の電流を合成させると”0”になるのです。対称3相交流は、各相とも同じ大きさでそれぞれが120°ずつ位相がずれているのでこのようになります。

ZCT is usually a neutral CT which happens to be dependant on zero sequence present-day detection. What comes about through leakage, The present while in the phases usually are not exactly the same & hence the in is not really equivalent to zero. This big difference of present flows into your neutral CT whicgh outings the RCCB

글보내기 기능을 제한합니다. 네이버는 블로그를 통해 저작물이 무단으로 공유되는 것을 막기 위해, 저작권을 침해하는 컨텐츠가 포함되어 있는 게시물의 경우 글보내기 기능을 제한하고 있습니다.

네이버는 블로그를 통해 저작물이 무단으로 공유되는 것을 막기 위해, 저작권을 침해하는 컨텐츠가 포함되어 있는 게시물의 경우 주제 분류 기능을 제한하고 있습니다.

11 Nov 09 09:52 Does any one understand how to convey to regardless of whether a currnet transformer is for zero sequence sensing and just a standard CT?  For example, I am investigating the solution website page for one mfr.  The solution site did not mention everything connected to zero sequence, so how do I realize whether it is for The actual software i am on the lookout for or not, Although it truly is lised below floor sensing item category.

These check here zero-section molded current transformers safeguard the ability technique versus leakage and earth faults. Each of these present transformers has an insulation degree of 0.72 kV and demands a suitably insulated Principal conductor.

네이버 아이디 또는 개인정보가 포함된 문자 사용은 피해주세요. 블로그 도움말에서 아이디 변경 유의사항을 확인해보세요. 나중에 할게요

ベクトルの和の平均値は「零相電流」と呼ばれ、上記のような対称形の場合、零相電流はゼロとなります。

จำหน่ายอุปกรณ์ไฟฟ้าแรงต่ำ-แรงสูงทุกชนิด อุปกรณ์ไฟฟ้าบ้าน อาคาร โรงงาน

Operating basic principle of CBCT or ZCT Kirchhoff's present legislation states that the full recent at every node of an electrical circuit will equivalent zero is the fundamental tenet governing how zero sequence recent transformers work. The vector sum of a three-stage procedure's phase latest (Ia + Ib + Ic = 0) is zero throughout standard Procedure. Consequently, the key winding of your CBCT is not going to include things like any leftover zero sequence current.

なお、下の記事は私(管理人)が書いた超概念的な内容です。もっと理論的な解説は鹿の骨さんが下さった以下を参照ください。

This ring sort current transformer can stability the zero sequence present-day inside the a few stage procedure. This is where it bought its title to be a Zero Sequence Existing Transformer (ZCT).

「零相変流器」というのは、系統に地絡事故発生した際に「地絡電流」を検出して取り出す変流器をいい、「地絡保護」用に用いる変流器です。「3相のベクトル合成した電気を物理的に取り出す」ことができる仕組みになっています。具体的な役割・構造について説明します。

Also, The volume of secondary turns of CT is not really expected based on the rated present of the cable for the reason that no secondary latest flows in typical functioning ailments since the three period program currents are well balanced.